SCI Assessed Banner

 

 

Sci Assessed Logo

 

SCI Assessed Companies

 

  • TAB-Deck
    Arcelor Tab-Deck system (comprising of a 30 kg/m³ dosage of HE 1/50 fibres) with SMD TR60 decking
  • Blind Bolt
    Design resistances of blind bolts in shear, bearing, tension, combined shear and tension, calculated for use with BS 5950-1 and BS EN 1993-1-8 and the UK National Annex, in 10.9 material, diameters 8, 10, 12, 16, 20 and 24mm.
  • MetFloor 55, MetFloor 60 and MetFloor 80
    MetFloor 55, MetFloor 60 and MetFloor 80. Deck profiles in 350 N/mm² material, at gauges of 0.9 mm, 1.0 mm, 1.1 mm and 1.2 mm and in 500 N/mm² material at a gauge of 1.2 mm).

    The single-span design properties of the deck profiles at the construction stage have been established from testing using statistical methods given by BS EN 1993-1-3: 2006 and BS EN 1990: 2002. The spanning capability of the deck profiles when used for two or more continuous spans have also been determined from tests.

    The interaction between the concrete and steel at the composite (or normal) stage has also been determined from testing in accordance with BS EN 1994-1-1: 2004 and BS EN 1990: 2002.

    Results are described in SCI report RT 1252.
  • Corus roof and wall cladding sheets
    Load tables in accordance with EN 1993-1-3 for a range of cold formed steel roof and wall cladding sheets and in accordance with EN 1999-1-4 for a range of aluminium roof and wall cladding sheets.
  • Euroclad roof and wall cladding sheets
    Load tables in accordance with EN 1993-1-3 for a range of cold formed steel roof and wall cladding sheets and in accordance with EN 1999-1-4 for a range of aluminium roof and wall cladding sheets.
  • Fusion Building Systems
    Linear thermal transmission values and temperature factor values for 12 standard details used in the Fusion light steel building system that are given in SCI Report RT 1264 (January 2009).
  • Kingspan composite floor decking
    A Kingspan published brochure (October 2007)on the acoustic performance of Kingspan composite floors including test results from laboratory acoustic tests and the predicted on-site acoustic performance of similar composite floors.
  • Sigma Purlins
    Load tables in accordance with BS 5950-5 for purlins produced by Midland Cladding Ltd, namely S390 steel “Sigma” sections in the following sizes; 145 × 65; 170 × 65; 200 × 65; 225 × 65 in material thicknesses of 1.3, 1.5, 1.7, 1.9, 2.1, 2.3 and 2.5mm
  • Tegral roof and wall cladding sheets
    Load tables in accordance with EN 1993-1-3 for a range of cold formed steel roof and wall cladding sheets and in accordance with EN 1999-1-4 for a range of aluminium roof and wall cladding sheets.
  • U-Roof
    A panelised light gauge roofing system particularly suitable for residential and light commercial applications. The system comprises lightweight panels and joist sections and includes a room in the roof solution as standard.

 

Contact Us Site Map Terms of Use Privacy Policy Update Policy © SCI 2006